Particulate Monitoring Systems Installation & Operating Manual
Document No. 210-1015-F Page 9 ©2007
4.3 Sensor Temperature Considerations
The sensor may be ordered with one of three process temperature ranges:
1. -40ºF to 250ºF (-40ºC to 121ºC)
2. -40ºF to 450ºF (-40ºC to 232ºC)
3. -40ºF to 800ºF (-40ºC to 426ºC)
Note: For the process temperatures in the range of 233ºC - 426ºC, a high temp probe must be used.
The maximum allowable ambient temperature at sensor housing is 70ºC.
Table: T Code Rating for Sensor
Process Temperature Does Not Exceed
Maximum Ambient
75ºC (167ºF) 125ºC (257ºF) 225ºC (437ºF) 325ºC (617ºF) 426ºC (800ºF)
70ºC (160ºF) T6 T4 T2C T1* T1*